29 07, 2020

Beam Instrument

We built the beam diagnostic system of CADS (Chinese Accelerator-Driven Subcritical System) linac Injector II, HIRFL SSC linac, and LEAF linac, which includes the measurements of current, position and phase (normal and cold BPM at cryogenic temperature), energy and energy spread, transverse profile and emittance, longitudinal bunch shape and so on. We also built the Ionization Profile Monitors (IPM) and the Schottky detectors for the CSRm and CSRe, which are all in operation very well. Now we are building the beam instrument system of SERSI linac and the injection line, HIAF linac, CiADS, as well as the IPM system for HIAF rings.

                                                                                     FFC detector and ES detector

                                                                                        Schottky detector

                                                                                              IPM structure

                                                                                       BPM electronics, 250 MS/s

                                                                                          Movable test bench